The Fluke 87V is a 4.5-digit True RMS industrial digital multimeter, renowned for its durability, precision, and advanced features, ideal for complex measurements in demanding environments like factories and laboratories.
1.1 Overview of the Fluke 87V Features
The Fluke 87V offers advanced features like True RMS measurement, data logging, and high accuracy for voltage, current, resistance, and temperature. It includes a 4.5-digit display, rugged design, and safety ratings for industrial use. The multimeter supports continuity testing, diode checks, and min/max recording. Its ergonomic design and intuitive interface make it ideal for field and lab applications, ensuring reliable performance in demanding environments.
1.2 Importance of the User Manual
The user manual is essential for understanding the Fluke 87V’s operation, safety, and features. It provides detailed instructions for measurements, maintenance, and troubleshooting. Reading the manual ensures proper use, safety compliance, and optimal performance. It also highlights advanced functions and setup guidelines, making it a crucial resource for both novice and experienced users to maximize the multimeter’s capabilities effectively and safely.
Safety Precautions and Guidelines
Always read safety information before use. Avoid measurements above 60V without caution. Ensure proper test lead usage to prevent electrical shock and ensure accurate, safe operation.
2.1 General Safety Information
The Fluke 87V requires adherence to safety guidelines to prevent hazards. Always read the entire user manual before first use. Avoid measurements exceeding 60V without proper precautions. Use test leads and probes as specified to prevent electrical shock. Ensure the meter is in good working condition to maintain accuracy and operator safety in all environments.
2.2 Warning Labels and Symbols
Warning labels and symbols on the Fluke 87V indicate potential hazards. These include high voltage, hot surfaces, and explosive environments. Always interpret symbols correctly to ensure safe operation. Refer to the user manual for detailed explanations of each label and symbol to prevent accidents and maintain operator safety during measurements and maintenance.
Product Overview and Specifications
The Fluke 87V is a 4.5-digit True RMS industrial digital multimeter, designed for durability and accuracy. It features advanced functions for measuring voltage, current, resistance, and temperature, making it ideal for industrial and field applications.
3.1 Key Features of the Fluke 87V
The Fluke 87V offers True RMS measurement for accurate AC readings, a 4.5-digit display for precision, and a rugged design for harsh environments. It measures voltage, current, resistance, and temperature, with advanced features like data logging and customizable power-up options. Its ergonomic holster and long battery life enhance usability, making it a reliable choice for industrial applications.
3.2 Technical Specifications
The Fluke 87V is a 4.5-digit True RMS multimeter with a 4000-count display. It measures DC voltage (10mV to 1000V), AC voltage (1mV to 1000V), current (1mA to 10A), and resistance (1Ω to 50MΩ). Frequency ranges up to 200kHz (voltage) and 100kHz (current). Temperature measurement spans -200°C to 1372°C. Accuracy is 0.1% for DC voltage and 0.5% for AC voltage. The device features a 4Hz to 200kHz bandwidth and CAT IV 600V safety rating.
Installation and Setup
Unpack the Fluke 87V, verify contents, and install the battery. Follow manual instructions for initial setup, ensuring proper calibration and function selection for accurate measurements.
4.1 Unpacking and Inventory
Upon receiving the Fluke 87V, carefully unpack and verify all contents against the provided list in the user manual. Inspect the multimeter and accessories for any visible damage. Ensure the battery is correctly installed and fully charged before initial use. Familiarize yourself with the included test leads, probes, and holster. Store all components securely to maintain functionality and organization for future use.
4.2 Battery Installation and Maintenance
Install the battery by aligning the terminals correctly and securing it in the compartment. Use alkaline batteries for optimal performance. Avoid mixing old and new batteries to prevent power issues. Remove the battery when not in use for extended periods to prevent discharge. Regularly inspect the battery for signs of wear or damage and replace it as needed to ensure reliable operation.
Operating Instructions
Start by selecting the desired measurement function using the mode button. Ensure test leads are properly connected and set to the correct range for accurate readings. Always refer to the safety guidelines before performing any measurement to avoid potential hazards and ensure reliable results.
5.1 Basic Measurement Functions
The Fluke 87V allows precise measurement of voltage, current, resistance, and continuity. For voltage and current, select AC or DC mode. Use the range button to set measurement scales manually. Resistance measurements are done using the OHMS function, while continuity testing checks circuit connections with a built-in buzzer. Always ensure test leads are securely connected to the correct terminals for accurate and safe readings.
5.2 Advanced Measurement Functions
The Fluke 87V offers advanced functions like temperature measurement using thermocouple probes and data logging for trend analysis. It also features auto-ranging for hands-free adjustments and a hold function to freeze readings. Additionally, secret functions like custom setups and calibration checks can be accessed by holding specific buttons during startup, enhancing versatility for specialized tasks and troubleshooting complex electrical issues efficiently.
Measurement Functions and Techniques
The Fluke 87V excels in measuring voltage, current, resistance, and continuity with high accuracy. It utilizes True RMS for precise AC voltage and current measurements, ensuring reliable results in various electrical environments.
6.1 Voltage and Current Measurement
The Fluke 87V accurately measures DC and AC voltage up to 1000V, and DC current up to 10A, with True RMS providing precise readings for non-sinusoidal waveforms. The multimeter’s high-resolution 4.5-digit display ensures accuracy, while its robust design withstands harsh environments, making it ideal for field and laboratory use in electrical and industrial applications.
6.2 Resistance and Continuity Testing
The Fluke 87V accurately measures resistance with a range up to 50 MΩ and includes a continuity test function with an audible buzzer for quick circuit checks. For continuity testing, manual ranging is required, and Figure 3-6 provides detailed setup instructions. Always ensure the circuit is de-energized before testing to avoid electrical shock, ensuring safe and reliable measurements in industrial and field environments.
Special Features of the Fluke 87V
The Fluke 87V offers standout features like True RMS measurement for accurate readings on non-sinusoidal waveforms and advanced data logging for monitoring measurements over time, enhancing its versatility in industrial applications.
7.1 True RMS Measurement
The Fluke 87V’s True RMS capability ensures accurate voltage and current measurements, even with distorted waveforms, providing reliable results in industrial environments where non-sinusoidal signals are common, thus enhancing measurement precision and reliability across various applications.
7.2 Data Logging and Storage
The Fluke 87V offers robust data logging capabilities, allowing users to record and store measurement data for later analysis. This feature is particularly useful for monitoring trends and troubleshooting intermittent issues. The multimeter can store a significant number of readings, which can be easily transferred to a PC via USB or compatible software, enhancing workflow efficiency and data management.
Maintenance and Troubleshooting
Regular maintenance ensures optimal performance and longevity of the Fluke 87V. Check for worn parts, calibrate as needed, and address common issues promptly to prevent measurement errors.
8.1 Routine Maintenance Tips
Regular maintenance ensures the Fluke 87V performs optimally. Inspect test leads and probes for wear, clean the multimeter’s exterior with a soft cloth, and verify battery health. Calibrate the device periodically as specified in the user manual to maintain accuracy. Store the multimeter in a dry, cool place, and replace any worn or damaged parts promptly to prevent measurement errors and extend its lifespan.
8.2 Common Issues and Solutions
Troubleshooting the Fluke 87V involves addressing common issues like inaccurate readings or display malfunctions. Check for loose connections, clean corroded terminals, and ensure proper battery installation. For faulty measurements, verify function selection and range settings. If issues persist, refer to the user manual for reset procedures or contact Fluke support for professional assistance to resolve complex problems effectively.
Calibration and Accuracy
Regular calibration ensures the Fluke 87V maintains precision. Follow manual procedures for adjustments and verification to guarantee accurate measurements across all functions, including voltage, current, and resistance.
9.1 Calibration Procedures
Calibration of the Fluke 87V ensures measurement accuracy. Refer to the manual for step-by-step adjustment procedures, including zero adjustment and full-scale calibration. Use the “Cal” function for precise adjustments. Ensure all internal and external calibration steps are followed to maintain reliability and precision. Regular calibration is essential for maintaining the meter’s accuracy across all measurement functions.
9.2 Ensuring Measurement Accuracy
To ensure accurate measurements with the Fluke 87V, use the true RMS function for precise readings of non-sinusoidal waveforms. Select the correct measurement range and avoid noise sources. Regularly calibrate the multimeter and verify probe condition. Use the “Cal” function for adjustments and refer to the manual for detailed calibration procedures. Proper technique and adherence to guidelines maximize measurement reliability and consistency.
Accessories and Compatibility
The Fluke 87V works with high-quality test leads and alligator clips for accurate measurements. It is compatible with Fluke’s software for data analysis and logging.
10.1 Recommended Test Leads and Probes
For optimal performance, use high-quality test leads and probes compatible with the Fluke 87V. Fluke recommends its own range of test leads and alligator clips for accurate measurements. These accessories are designed to ensure reliability and safety during testing. Using genuine Fluke test leads and probes guarantees compatibility and maintains the meter’s precision and accuracy in various environments.
10.2 Software Compatibility and Usage
The Fluke 87V is compatible with Fluke’s software tools, such as PQ Analyze, for enhanced data logging and analysis. Users can connect the multimeter to a PC via USB or other interfaces to transfer measurement data. Software compatibility allows for detailed trending, reporting, and storage of results, making it ideal for industrial and diagnostic applications. Refer to the user manual for specific software installation and operation instructions.
Warranty and Support
The Fluke 87V is backed by a 3-year warranty, covering defects in materials and workmanship. For support, contact Fluke directly via phone or their official website.
11.1 Warranty Information
The Fluke 87V is covered by a 3-year warranty, ensuring protection against defects in materials and workmanship. This warranty period begins from the date of purchase, providing users with assurance of reliability and support. Fluke stands behind the quality of their products, offering repair or replacement options during this period. For detailed terms, refer to the official Fluke website or contact their support team directly.
11.2 Contacting Fluke Support
For assistance with the Fluke 87V, users can contact Fluke support via phone or through their official website. Regional support numbers are available for quick service, ensuring help is accessible worldwide. Additionally, online resources, including FAQs and service centers, provide comprehensive support. Fluke’s dedicated team is ready to address inquiries, repairs, and technical questions promptly, ensuring optimal use of the multimeter.
Advanced Tips and Tricks
Explore secret functions by holding buttons during startup. Optimize measurements by using the multimeter’s advanced features, ensuring precise and efficient troubleshooting in industrial environments.
12.1 Optimizing Measurement Speed
To enhance measurement speed, ensure the multimeter is set to the correct range and function. Utilize autoranging for quick adjustments and enable the fast sampling rate for real-time data capture. Regularly update the firmware and use the Fluke Connect® software for seamless data transfer and analysis, improving overall efficiency in industrial applications.
12.2 Using Secret Functions and Power-Up Options
The Fluke 87V features hidden functions activated by holding specific buttons during startup. These include faster measurement modes and specialized display settings. To access power-up options, press and hold function keys while powering on. Refer to Table 5 in the manual for details on activating these advanced features to customize your multimeter’s performance for unique testing scenarios.
The Fluke 87V is a robust, precise, and feature-rich digital multimeter designed for industrial environments, ensuring accurate and reliable measurements with advanced functionality and durability.
13.1 Summary of Key Features
The Fluke 87V offers True RMS measurements, 4.5-digit resolution, and a 4000-count display, ensuring accuracy for complex signals. It includes advanced functions like data logging, temperature measurement, and power-up options. Its durability and ergonomic design make it ideal for industrial use. The device supports various probes and is compatible with Fluke software for enhanced functionality and analysis.
13.2 Final Tips for Effective Use
Always follow safety guidelines and calibrate the Fluke 87V regularly for accuracy. Use appropriate test leads and probes for precise measurements. Explore advanced features like data logging and power-up options to optimize functionality. Refer to the user manual for troubleshooting common issues. Regularly maintain the device to ensure longevity and reliability in demanding environments. Proper storage and handling will extend its lifespan and performance.